{"product_id":"onesto-6a-250v-500v-6ka-dc-2-pole-circuit-breaker","title":"Onesto 6A 250V - 500V 6kA DC 2 Pole Circuit Breaker","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Onesto KCD6 6A double-pole DC miniature circuit breaker provides overload and short-circuit protection for correctly specified direct-current circuits. Its 2-pole DIN-rail format suits compatible distribution boards and control panels, with a 6kA breaking capacity and a maximum operating voltage of 500V DC when connected in the manufacturer's prescribed pole arrangement.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e6A rated current for circuits designed around this protection rating.\u003c\/li\u003e\n\u003cli\u003e2-pole configuration for linked operation of the breaker poles.\u003c\/li\u003e\n\u003cli\u003e6kA short-circuit breaking capacity for installations with a suitable prospective fault current.\u003c\/li\u003e\n\u003cli\u003e500V DC maximum operating voltage with the correct manufacturer-specified wiring.\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting for installation in compatible electrical enclosures.\u003c\/li\u003e\n\u003cli\u003eDesigned to protect and control DC circuits against overloads and short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDC distribution boards and control panels requiring 6A 2-pole circuit protection.\u003c\/li\u003e\n\u003cli\u003eDomestic and industrial DC electrical installations within the specified ratings.\u003c\/li\u003e\n\u003cli\u003eSolar-related DC circuits where the voltage, fault level, conductor size and pole arrangement meet the installation design.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose This Product?\u003c\/h3\u003e\n\u003cp\u003eThis breaker offers a compact Onesto protection option for installers who require 6A DC circuit protection in a 2-pole format. It forms part of the KCD6 range, allowing the current rating to be selected to suit the circuit while retaining a consistent DIN-rail installation format.\u003c\/p\u003e\n\u003ch3\u003eImportant Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstallation and device selection must be completed by a qualified electrician in accordance with applicable South African wiring requirements and the manufacturer's instructions.\u003c\/li\u003e\n\u003cli\u003eThe 500V DC rating applies to the complete 2-pole assembly with the prescribed pole connections. Do not assume that each individual pole can interrupt 500V DC.\u003c\/li\u003e\n\u003cli\u003eObserve the device's polarity, supply\/load markings and wiring diagram, including any required series connections between poles. Do not infer the positive and negative conductor arrangement from the pole count alone.\u003c\/li\u003e\n\u003cli\u003eSelect the current rating and trip characteristic to suit the load, conductor size and prospective fault current. Verify the trip characteristic against the supplied unit's marking before installation.\u003c\/li\u003e\n\u003cli\u003eThis is a DC circuit breaker. Pole count does not indicate an AC phase rating, and an AC-only breaker must not be substituted.\u003c\/li\u003e\n\u003cli\u003eProduct images illustrate the range; the current rating printed on the supplied unit will match the ordered version.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOnesto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Range\u003c\/td\u003e\n\u003ctd\u003eKCD6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplier Product Code\u003c\/td\u003e\n\u003ctd\u003eGL1CDC2006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDC miniature circuit breaker (MCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2P \/ double-pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaks\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e250\/500V DC (local catalogue)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e500V DC with the manufacturer-specified pole arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Breaking Capacity\u003c\/td\u003e\n\u003ctd\u003e6kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Impulse Withstand Voltage\u003c\/td\u003e\n\u003ctd\u003e6kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Onesto","offers":[{"title":"Default Title","offer_id":50685996499184,"sku":"SUS-GL1CDC2006","price":344.95,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0601\/7623\/6737\/files\/2_pole_6ka_dc_circuit_breaker_800px_1_b784ac77-7029-4aab-bcd3-a7136c983855.jpg?v=1793194735","url":"https:\/\/www.sustainable.co.za\/products\/onesto-6a-250v-500v-6ka-dc-2-pole-circuit-breaker","provider":"Sustainable","version":"1.0","type":"link"}