Technical Specifications
- Operating Voltage: 230Vac / 50Hz.
- Main relay contact rating: 30A (Max. 4kW).
- Temperature probe failure detection for both collector and tank.
- Temperature probe range for geyser: - 30° to 130°C.
- Temperature probe range for collector: -30 to 260°C.
- Isolates both Live and Nutral in off state.
- Secondary Relay pump and solenoid: 5A.
- Operating Voltage Range: 160V - 250V AC.
- Earth leakage protection @ 24mA action time ≤0.1 Second.
- Temperature display range 0° - 99°C.
- High temperature warning above 84°C.
- Temperature setting ranges 30° - 65°C.
- Heat Failure- when increasing at a rate of less than 4°C per hour.
- Electronic thermostat with mechanical themal cut-out at 90°C.
- Dry heat detection (Empty Cylinder).
- Temperature tolerance: -2%.
- Temperature differential setting: 1°C.
- Switching differential: 6°C.
- Second temperature probe for solar.
- Solar differential 7°C; Collector antifreeze protection at 5°C.